3.2 FBDA ALARM SPECIFICATIONS
Remote Fault Indication
(Summarized alarm)
Relay Contact open for any fault. Relay closed for no fault.
Alarm is sent on the serial data link of the FO transmitter
Fault List : Power Supply Over-voltage or Under-voltage
Uplink Amplifier Over Current or Under Current
Downlink Power Amplifier Over Current or Under Current
FO Transceiver Over Current or Under Current
FO Receiver Power fall (Bad Optical Connection)
Fan Over Current or Under Current
High temperature
Electrical Fault
Indication LED
Illuminated LED on Monitor Box for each Electrical Fault
Fiber Optic Connection
Fault Indication LED
Illuminated LED on FO Transceiver when Optical
Connection is performing Correctly.
LED is OFF when FO Receiver Power falls.
3.3 MECHANICAL SPECIFICATIONS:
Size : 400 x 400 x 300 mm approx.
RF Connectors : N-type Female
Weight : 30 kg. Approx.
Enclosure Type : Weather proof Enclosure
for Wall Mounted Installation(IP66).
Power Supply : 100 to 220 VAC / 2A
3.4 ENVIRONMENTAL CONDITIONS:
6.1 Operating temperature
: - 20
°
C to + 50
°
C
6.2 Storage temperature
: - 30
°
C to + 70
°
C
Page 12 of 15 FBDA-800AB-50wDIV-INSTL1.doc