User's Manual

PRODUCT MANUAL DEKO4078SD MULTI-CHANNEL SIGNAL BOOSTER DEKOLINK WIRELESS LTD.
P/N 300SC30031 Rev. 1.2 Proprietary Data Page 63
5. Click the Connect button in order to establish a connection between the unit
and the application.
6. Provision the system according to the following section.
CONFIGURING THE BOOSTER PARAMETERS
The booster parameters are displayed with default values, however these can be
modified according to site requirements. The following configurable booster
parameters are displayed in the 700 and 800 band windows:
Max Power
Max Gain
Low and high RSSI threshold levels
Output Power Threshold
To configure the signal booster parameters
In the 700 and 800 band windows, define the configurable parameters (listed above)
according to site requirements and click the Send Parameters button at the bottom
of the window. The status of this operation is shown in the
Status
bar.
Note: The modified parameter values will appear in red until the Send Parameters button
is clicked. After the parameters have been sent and written on to the DMSB unit, the
values are shown in black.
The measured values of the unit are displayed in the RSSI, System Gain, Digital Gain
and Measured Output Power columns. These are read-only parameters.
Send
Parameters
Status Ba
r