Click the Digital Filters Application button in the Repeater Interface screen
Select Tools / Read Filters in the Menu bar
Click Yes in the dialog box. The current digital filter configuration in the
Repeater is displayed
Set the filter configuration (number of filters, frequencies and filters type) in
the Downlink page
Activate the relevant channels by clicking in the On/Off checkbox
Select the Uplink tab and set the digital filter configuration accordingly.
After defining the digital filters (Downlink and Uplink), download the new data to the
repeater so that the information can go into effect.
6.1.3 Saving the Settings
Two ways to save the settings into the repeater are available:
Download to RAM for temporary setting, and
Burn-in to Flash for permanent setting.
To savethe settings:
Click
Download to RAM.
This technique is recommended for trials, tests and preliminary setup of the
digital repeater until the final configuration of the digital filters is achieved.
You can download the settings an unlimited number of times using
Download to RAM.
This process is however volatile and the information will be lost in the event
of a power failure. The DDF parameters are kept in a volatile memory only,
and should be burned to a Flash memory at finalization of the process.
Click the
Burn-in to Flash button to download the data to a non-volatile
(FLASH) memory.
You can download the data to the Flash memory a relatively large but
limited number of times (several hundreds). It is recommended to burn the
data into the Flash memory only, after you are satisfied with the filter
settings for the required application and intend to use it for long period of
time.
To finalize the procedure:
Disable the Mute for the downlink and uplink amplifier and test the
performance in the coverage area. (Mute is the output power on/off control,
which can be set via “P.Amp On” checkbox.)
Save the configuration files of the digital filters by selecting
File / Save configuration in the Digital Filter Application and assigning a
appropriate name to the file. This data is not saved in the RMT Database.