IDEN REPEATER PRODUCT MANUAL DEKOLINK WIRELESS LTD.
3.4.3 RF Gain Setting
The gain value should be set via the RMT in accordance with the input signal power
at the Donor antenna, and the required Downlink output power. Special care should
be taken not to exceed the isolation limit. It is recommended to set the Downlink
path gain to a maximum value that is 12 dB below the isolation between the Base
antenna and the Mobile antenna.
The gain range is 59-90 dB. Use the Max Gain field for Downlink GAIN setting and
the Gain Delta field to determine the GAIN difference between Uplink and Downlink
path (Uplink GAIN follows Downlink GAIN by “Delta” dB).
Refer to Section 5.5
Note
When you set the gain to 60 dB the Maximum Output Power will degrade due to
overload input power. The maximum input power you can inject is –25 dBm.