Installation Instructions
Table Of Contents
Dekolink Wireless Ltd.;16 Bazel St.Qiryat-Arieh Petah-Tikva Israel, 49510
Tel- 972-3-9180-180; Fax-972-3- 190-9180 ;
Email-marketing@dekolink.com
:TRICAL SPECIFICATIONSELEC
Frequency Range (MHz) SEE TABLE
Passband Gain @Min attenuation 80 dB nominal
Passband Ripple
± 1.5 dB typical
Manual Attenuation Range 0 to 30 dB in 2 dB step
Noise Figure 6.0 dB max
Impedance level 50 ohms
V.S.W.R In/Out 1.5 : 1 max
AGC Selection By ON/OFF Switch
AGC Attenuation Range 25 dB typical
AGC LED Indication LED turn ON when power reaches AGC Set
Power Level. (both at On and Off positions).
AGC Factory Power Preset Up link: +24 dBm nom.
Down link: +30 dBm nom.
Amplifier Power Output
@1 dB Compression
Up Link : 1 Watts
Down Link : 10 Watts
3rd Order output Intercept point Up Link : +45 dBm typical
Down Link :+50 dBm typical
Power Supply 110/220V AC, 50-60 Hz /1A
System Frequency Range
SYSTEM TYPE
MODEL No
DOWN-
LINK
UP-
LINK
E-SMR (iDEN) MW-CBDA-ESMR-10W80A 851-866 806-821
SMR 800-Public Safety MW-CBDA-SMR-10W80-PS8 851-869 806-824
SMR - 900 MHz MW-CBDA-SMR-10W80A-PS9 935-941
89
6-902
GSM MW-CBDA-GSM-10W80A 935-960 890-915
TDMA Band B MW-CBDA-CELLB-10W80A 880-894 835-849
CDMA/TDMA/N-AMPS MW-CBDA-AB-10W80A 870-894 825-849
;
Web site- www.dekolink.com rev 5 11/02 page 9 of 12