Diagnostic Guide
The CBDA provides long term, carefree operation and requires no periodic
maintenance.
This section covers possible problems related to the installation environment.
Top Cover LED Indications
Once the CBDA is installed the red LEDs on the top cover indicate uplink and downlink
faults.
The green LED is AC power on indication.
Indication Cause Action
Downlink LED (on
cover) is ON
Indicates low RF power at
downlink path <15 dBm)
Check base antenna connection.
Check antenna alignment to base.
Use higher gain BDA
Uplink Amp LED (on
cover) is ON
Uplink amplifier over current
or undercurrent fault
Replace CBDA
These faults can be sensed remotely from the dry contact relay arms wired to the D9
connector at the back of the CBDA.
Alarm relay connection to D connector:
Pin 2 to 4 open at any fault; short at no fault