User's Manual

Page 11 of 14 50W rev 3 - 11/ 03
Dekolink WIRELESS Ltd.
16 Bazel St. Qiryat-Arieh Petah-Tikva, Israel, 49510
Tel- 972-3-9180-180 Fax-972-3- -
e-mail: marketing@decolink.com web www.decolink.com
ELECTRICAL SPECIFICATIONS:
SPECIFICATIONS PARAMETER
Down Link Up Link
Frequency Range 851-866 MHz 806-821MHz
Gain 90±4 dB
Pass Band ripple <3 dB p-p
Manual Attenuation Range 0 to 30dB in 2dB Step
Noise Figure 5dB
Output Power @ 1 dB compression 50W 16W
3
rd
order intercept point 62 dBm typ. 50 dBm typ.
Composite Power Output, max +40dBm +31dBm
Down Link IMD @ two tone 37dBm each 50 dBc --------------------
Up Link IMD @ two tone
27dBm each
------------------- 44 dBc
AGC Factory set level (nom.) 40 dBm 31 dBm
AGC range 15 dB 20 dB
Impedance 50 Ohms
VSWR <1.5:1
Rx/Tx Isolation > 100 dB
Fault Monitoring LED indication for each fault
Remote Alarm Summarized alarm by dry contact
Power Supply AC 110/220V/50Hz Range: 176~264V, 45~65Hz
Option +28 VDC
Mechanical Specifications:
Size 400X400X300 mm approx.
RF Connectors N-type Female
Weight 30 kg. Approx.
Enclosure Type Weatherproof Enclosure for Wall Mounted
Installation
Environmental Conditions:
Operating temperature
-30°C to +50°C
Humidity 95%
Weatherproof conditions Protected to IP65