Installation guide

3-3 RUN TIME 12, 24, 60 MINUTES: Selects the time in minutes that the system will
operate the engine until the system "times out". This is the maximum operation period and
the system may be shut down using a shutdown at any time. Using the Bitwriter, the run time can
be programmed for any duration from 1-60 minutes.
3-4 PARKING LIGHTS FLASHING/CONSTANT: In the default setting, the unit will flash the
vehicle's parking lights (if connected) while remote started. The constant setting will turn the
parking lights on solid for the entire run duration.
3-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 SECONDS: If the unit is programmed for
no engine checking or voltage sense, the crank time must be set to the appropriate duration. The
default setting is 0.6 second. If a different crank time is desired, select feature 3-5 and select either
0.6 second by using the one-chirp setting or toggle through the higher settings by using the two-
chirp settings.
3-6 VOLTAGE CHECK HI/LOW: This feature only functions when programmed for voltage sense.
Some vehicles have many accessories, which are turned on when remote started. In these vehicles,
the variation of voltage between the engine off and the car running is very small and the remote
engine starting unit may "think" the vehicle has not started. This can cause the remote engine
starting system to shut-down after the car has been started. If this happens program this feature to
the LOW position.
3-7 AUXILIARY OUTPUT FACTORY DISARM/SPECIAL ACCESSORY: In the default setting this
wire sends a negative pulse that may be used to disarm the vehicles factory security system. If
programmed for a special accessory, the wire can be used to energize a relay to power up extra
ignition wires in the vehicle. This wire must be used to energize circuits in the vehicle that operate
accessories, such as the radio or heater.
3-8 BLUE WIRE STATUS OUTPUT/FACTORY SECURITY RE-ARM OUTPUT: The blue
(H3/1) wire will supply a 200mA (-) output for the entire remote start run time. If programmed
for factory re-arm output, this wire will supply a momentary 200mA (-) pulse whenever the remote
engine starting system times out or is shut down with the transmitter. This can be used to re-arm
many factory security systems.
3-9 AUTOMATIC ANTI-GRIND ON/OFF: With the anti-grind ON (default) the ground-when-
armed output will be active during remote start operation. If accessories such as a voice module or
window module are added to the unit, it may be necessary to program this feature OFF.
38
©
2001
Directed Electronics, Inc.