Data Sheet
10/11/2019
www.sunny-euro.com
30-60W
Wall mount
SYS1621-Wxx series
Country of Origin :
Operating Temperature :
Dimension :
Efficiency level (ErP) :
China
0~40 [°C]
58 × 58 × 28 [mm] (for 30W model)
65 × 65 × 28[ mm] (for 45&60W models)
VI
RoHS
GREEN MODE
Approvals / Marks :
Specifications
Model
Voltage DC/Loading
[V/A]
Max. Power
[W]
Ripple / Noise
[mV] p-p
Connector
SYS1621-Type C 30 5V/3A, 9V/3A, 12V/2.5A, 15V/2A, 20V/1.5A 30 150 USB-C
SYS1621-Type C 45 5V/3A, 9V/3A, 12V/3A, 15V/3A, 20V/2.2A 45 150 USB-C
SYS1621-Type C 60 5V/3A, 9V/3A, 12V/3A, 15V/3A, 20V/3A 60 200 USB-C
Features:
PSU housing ready for use in country : Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan (fixed) | W2A - Australia | W2G - Argentina | W2K - Korea
Output connector: Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty | Power delivery
OUTPUT
Turn delay
5000 ms max @ AC low line input@output full load
Hold up time
10ms min@AC nominal input@output full load (>half cycle)
Efficiency (Normal)
Meet CEC,DOE,ERP,MEPS Level
VI@115v/60HZ,230V/50HZ
Transient response
(dv,tmax)
0.4v dv max At AC nominal input loading from 50% load to
max load or peak load
16ms tmax | Dynamic rise time 10uS max duty 40mS max ,
Dynamic load step is slew rate of 0.5A/uS
Power out.Limit
30-60W based on the model
Burn in limit
Full load 2 Hours
Power consumption
0.075W for Type C 30W and 45W
0.15W for Type C 60W
Output regulation
Auto-detect the charging voltage and current for Type C and
iOS devices. Meet PD3.0,QC 3.0 requirements rules
INPUT
Voltage
(90~264)VAC
Frequency
(47~63)hz
Current
1.5A rms @ AC low line input and DC output full load
Inrush Surge Current
(cold start)
40/60A max@power supply cold start,ambient temperature
25°C @115Vac/230Vac nominal AC input
leakage current
0.25mA Max
PROTECTION
Over current/
Short protection
The power supply will self-protect any output to ground &
auto recovery when abnormal circuit faults remove. An
output short circuit is defined as any output impedance less
than 0.1 ohms.
Over Voltage
The power supply will be auto recovered when faults remove
Input protection
F1 2A/250V Fuse The power supply shall be protected
against power line surges and any abnormal condition
No Load protection
The power supply is provided with no load operation to
prevent the power supply and system from damage.
Protection class
II
CE
EMC
2014/30/EU
LVD
2014/35/EU
EN 62368-1:2014+A11:2017
SAFETY
CE | FCC
OTHERS
Dielectric Strength(Hi-pot)
Primary to Secondary:3000VAC 10mA/60S
M.T.B.F
500,000 Calculated Hours at 25ºC, by Telcordia SR-332
DC output
Type C
PLD
(power line disturbance)
Line power surge | Line voltage SAG-more info on request
Cooling method
Natural Convection Cooling
Housing material
PC
Temperature coefficient:
<±0.5%/℃
ENVIRONMENT
Temperature
Operating: 0~40℃ / Storage: -20~85℃
Humidity
Operating: 8%~90%RH / Storage: 5%~95% RH non condens-
ing
WEIGHT
NW: 150g/pc
GW: 16kg/box
PACKING
PE plastic bag 100 pcs /1 box