Data Sheet

22.2.2021
Country of Origin :
Operating Temperature :
Dimension :
Certified AC Plugs:
Efficiency level (ErP) :
China
0~40 [°C]
80x 58x 39 [mm]
EU, UK, USA/Japan/Taiwan, Aus, China, Korea
VI
30W~40W
Wall mount
SYS1588-Wxx series
Specifications
Model
Voltage DC
[V]
Loading
[A]
Max. Power
[W]
Ripple / Noise
[mV] p-p
Connector
[mm]
SYS1588-2505-Wxx* 5 0~5 25 120 2.1x5.5x11
SYS1588-3609-Wxx* 9 0~4 36 120 2.1x5.5x11
SYS1588-4012-Wxx* 12 0~3.3 40 200 2.1x5.5x11
SYS1588-4015-Wxx* 15 0~2.6 40 200 2.1x5.5x11
SYS1588-4018-Wxx* 18 0~2.2 40 240 2.1x5.5x11
SYS1588-4024-Wxx* 24 0~1.6 40 240 2.1x5.5x11
SYS1588-4048-Wxx* 48 0~0.8 40 400 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China | W2K - Korea
Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified
Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty
OUTPUT
Turn delay
3000 ms max@AC low line input@output full load
Hold up time
8ms min@AC nominal input@output full load
Efficiency (Normal)
>87%@115v/60HZ,230V/50HZ input &Full load
Transient response
(dv,tmax)
0.4V dv max At AC nominal input loading from 20%load to 80%
load
16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us
Power out.Limit
40W
Burn in limit
Full load 2 Hours
Power consumption
0.1W max. At AC nominal input@output min load
INPUT
Voltage
(90~264)VAC
Frequency
(47~63)hz
Current
1.5A rms@AC low line input and DC output full load
Inrush Surge Current
(cold start)
40/60A max@power supply cold start,ambient temperature 25°C
@115Vac/230Vac nominal AC input
leakage current
0.25mA Max
PROTECTION
Over current/
Short protection
The power supply will be auto recovered when over current or
short circuit faults remove (fold back). Is defined as any output
impedance of less than 0.1Ω.The power supply will be auto
recovered when short circuit faults remove
Over Voltage
The power supply will not be auto recovered when faults remove
110%-150%. (Voltage limit)
Input protection
F1:2A 250V Fuse The power supply shall be protected against
power line surges and any abnormal condition
No Load protection
The power supply is provided with no load operation to prevent
the power supply and system from damage.
Protection class
II, (ITU-T K.21 Surge 6KV on request)
CE
EMC
2014/30/EU
LVD
2014/35/EU
EN 60950-1:2006+A11+A1+A12+A2
EN 62368-1
SAFETY
CE | GS | cTUVus | FCC | RCM | PSE | EAC | CB
OTHERS
Dielectric Strength
(Hi-pot)
I/P-O/P:3000VAC
M.T.B.F 500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Cable Length
1370mm (4.5 feet) standard cable or as required
PLD
Line power surge | Line voltage SAG-more info on request
Cooling method
Natural Convection Cooling
Housing material
PC + ABS
Temperature coefficient:
< ±0.5% / °C
ENVIRONMENT
Temperature
Operating: 0~40 / Storage: -20~85
Humidity
Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
WEIGHT
NW: 173g/pc + plug
GW: 193g/pc + plug
PACKING
Box
75 pcs/1 box
Approvals / Marks :
www.sunny-euro.com
RoHS
GREEN MODE