Data Sheet
22.10.2019
www.sunny-euro.com
12W
Wall mount
SYS1381N-Wxx series
Country of Origin :
Operating Temperature :
Dimension :
Efficiency level (ErP) :
Approvals / Marks :
China
0~40 [°C]
63.6 x 29.5 x 45.6 [mm]
VI
RoHS
GREEN MODE
Specifications
Basic Models
Voltage DC
[V]
Loading
[A]
Max. Power
[W]
Ripple / Noise
[mV] p-p
Connector
[mm]
SYS1381N-1205-Wxx 5 0~2.4 12 150 2.1x5.5x11
SYS1381N-1206-Wxx 6 0~2.0 12 150 2.1x5.5x11
SYS1381N-1207-Wxx 7,5 0~1.6 12 150 2.1x5.5x11
SYS1381N-1209-Wxx 9 0~1.33 12 150 2.1x5.5x11
SYS1381N-1212-Wxx 12 0~1.0 12 150 2.1x5.5x11
SYS1381N-1215-Wxx 15 0~0.8 12 180 2.1x5.5x11
SYS1381N-1218-Wxx 18 0~0.66 12 200 2.1x5.5x11
SYS1381N-1224-Wxx 24 0~0.5 12 250 2.1x5.5x11
Features:
Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China
For all models, the minimum rising step of output voltage is 0.1V - 4.0V~24V 12W max | Private Label Marking Available | 2 Years Warranty
OUTPUT
Turn delay
5000ms max@AC low line input@output full load
Hold up time
10ms min@AC nominal input@output full load
Efficiency (Normal)
>79.94%min. Eff= 0.071 x In(Po/1W) - 0.0014 x Po/1W + 0.67
Directive EU 2019/1782
load or peak load.
Transient response
(dv,tmax)
16ms tmax Dynamic rise time 10 us max,duty 40ms
max,Dynamic load step is slew rate of 0.5A/us
Burn in limit
Ambient temp: 35C+-3%; 80% load; input voltage 230V; 2 hours.
Power consumption
0.1W max. At AC nominal input@output min load
INPUT
Voltage
(90~264)VAC
Frequency
(47~63)hz
Current
0.5A rms@AC low line input and DC output full load
Inrush Surge Current
(cold start)
40/60A max@power supply cold start,ambient temperature 25°C
@115Vac/230Vac nominal AC input
leakage current
0.25 mA max
PROTECTION
Over current/
Short protection
The power supply will self-protect any output to ground, And auto
recovery when abnormal circuit faults remove. An output short
circuit is defined as any output impedance of less than 0.1 ohms.
Over Voltage
The power supply will not be auto recovered when faults remove
110%-150%. (Voltage limit)
Input protection
F1:1A /250V Fuse. The power supply shall be protected against
power line surges and any abnormal condition
No Load protection
The power supply is provided with no load operation to prevent
the power supply and system from damage.
Protection class
II
CE
EMC
2014/30/EU
LVD
2014/35/EU
EN 60950-1:2006+A11+A1+A12+A2
EN 62368-1
SAFETY
CE | CB | TUV/GS
OTHERS
Dielectric Strength
(Hi-pot)
HI-POT B / IEC 320 2pin primary to secondary 4000Vdc 10mA
1min
M.T.B.F
500,000 Calculated Hours at 25ºC, by Telcordia SR-332
Cable Length
1370mm (4.5 feet) standard cable or as required
PLD
(power line disturbance)
Line power surge | Line voltage SAG-more info on request
Cooling method
Natural Convection Cooling
Housing material
PC
Temperature coefficient:
< ±0.5% / °C
ENVIRONMENT
Temperature
Operating: 0~40℃ / Storage: -20~85℃
Humidity
Operating: 8%~90%RH / Storage: 5%~95% RH non condensing
WEIGHT
NW: 69 g/pc (without plugs) + W2E plug 24g; W3U plug 19g; W2 plug 13g; W2A plug 13g
GW: 89 g/pc (without plugs)
PACKING
Box
100 pcs/1 box