Instructions

Specifications subject to change without notice
ATS 200T-S Desktop with Switch 192 W 200 W
Product similar to photo, variations possible
Features
Compliant to DoE 2016 (Level VI)
ErP Stage 2, NRCan & GEMS Level VI
No Load Power Consumption < 0.1 W
Regulated Output with Low Ripple Noise
1 Year Warranty
Marks / Approvals
Specifications
MODEL
Voltage
Min. Load
Max. Load
Max. Power
ATS 200T-P240S
24 V
0.00 A
8.3 A
199 W
INPUT
AC 100 V 240 V
50 Hz - 60 Hz
2.8 A max.
Internal Primary Current Fuse, Inrush Limiting
OUTPUT
± 5 % (typical)
1 % 2 % V p-p max. for output voltage at full load
0.5 ms for 50 % load change typical
0.25 mA max.
Short circuit Protection Over Voltage ProtectionOver Current Protection
OTHERS
Convection
DoE Level VI ▪ Energy Star ▪ ErP Stage 2 ▪ NRCan & GEMS Level VI Certified
10 ms at full load
AC 3000 V Primary Secondary
300,000 calculated hours at 25 °C by Telcordia SR-332
ENVIRONMENT
Operating: 0 °C 40 °C / Storage: -20 °C 80 °C
Operating: 20 % RH 80 % RH / Storage: 10 % RH 90 % RH
CONNECTION
IEC 60320 C14 input connector (Protection Class I)
12 V; 24 V: Black cable UL2464 AWG16*4C, cable length: 150 cm, 4 pin DIN plug
48 V: Black cable UL2464 AWG16*2C, cable length: 150 cm, Plug 5.5 x 2.5 x 9.5 mm
EMI Conduction &
Radiation
Compliance to EN 55022 Class B
Harmonic Current
Compliance to EN 61000-3-2, -3
EMS Immunity
Compliance to IEC 61000-1-2, -3, -4, -5, -6, -8, -11
Safety
IEC / EN / UL 62368-1 ▪ IEC 60950-1 ▪ CE ▪ PSE
Case Dimensions
203.2 mm x 81.0 mm x 42.3 mm
Weight
850 g (typ.)