Datasheet
ZDD 120100m-N 12 W
Specifications
Dimensions: 70 mm × 46 mm × 35 mm
Efficiency Level: ErP Stage 2, CEC Level V
Marks / Approvals:
OUTPUT
MODEL
VOLTAGE
MIN. LOAD
MAX. LOAD
MAX. POWER
ZDD 120100m-N
12 V
0.0 A
1 A
12 W
Standby Power Consumption
Less than 0.3 W
Load Regulation
± 5 % (typical)
Ripple & Noise
120 mV p-p
INPUT
Voltage
AC 100 V – 240 V
Frequency
50 Hz – 60 Hz
Current (rms max)
0.5 A max.
Leakage Current
0.25 mA @ 2 pins
PROTECTION
Over Current
Yes
Overvoltage
Yes
Short Circuit
Yes
Input
Internal Primary Current Fuse, Inrush Limiting
No Load Operation
Yes, to protect the power supply and system from damage
OTHERS
Cooling
Free air convection
Withstand Voltage
AC 3000 V Primary - Secondary
Transient Response
Within 4 % of steady state
Holdup time
10 ms @ full load
ENVIRONMENT
Temperature
Operating: 0 °C to 40 °C / Storage: -20 °C to 65 °C
Humidity
Operating: 10 % RH to 90 % RH / Storage: 10 % RH to 90 % RH
CONNECTION
Input
Optional Interchangeable Plugs:
EU: CEE 7/16 Europlug
US: NEMA1-15P
UK: BS 1363
AU: AU/NZS 3112
Output
Standard DC plug: 2.1 mm × 5.5 mm × 9.5 mm / DC Cord: 22 AWG 2464 (150 cm)
MTBF
35,000 Calculated Hours at 25°C, by MIL-HDBK-217F
SAFETY
CB / UL / cUL / FCC / GS / CE / PSE / BSMI / LPS
EMI
Compliance to EN 55022 Class B, EN 61000-3-2, -3, FCC Part 15 Class B, AS/NZS3548, AS/NZS4251.1 Class B
EMS
Compliance to EN 61000-4-2, -3, -4, -5, -6, -8, -11
DIMENSIONS
70 mm × 46 mm × 35 mm
NET WEIGHT
120 g (ref.)
Features
■ Optional Interchangeable Plugs
■ Wide Input Range AC 90 V to 264 V
■
No Load Power Consumption Less Than 0.3 W
■ Low Ripple & Noise
■ 1 Year Warranty