Specifications

22
Addapted Lubricants for DEGERtraker 5000NT:
5.2 Maintenance
The DEGERtraker 5000NT is designed for as less as possible service- and maintenace work to
do. For a safe and long-life running of the system it is necessary to do the following jobs
periodically once a year:
- controll all screws and tighten them up to the torque given in the assembly instruction.
- controll all moving parts and lubricate them again if necessary. Pay special attention to the
IMO.
Mounting screw
Dimensions
Tightening torque M
A
1)
in Nm
screw strength class
M6 7,8
M8 19,1
M10 38,0
M12 66,5
M14 107,0
M16 168,0
1) M
A
according to VDI-guideline 2230 (Feb. 2003) for µ
A
=0,08 and µ
B
=0,12
Supplier Product name
Avia Avialith 2 EP -30 +130
Bechen High-Lub L 474-2 -20 +120
Bechen Beruplex EP-O -35 +150
Bechen RHUS LT 2 EP -25 +120
Castrol Longtime PDD -40 +140
Fuchs Renolit Duraplex EP2 -30 +160
Rhenus Norplex LKP2 -20 +150
Applicable