Secure the hose by tightening the hose clamp.
Repeat the same procedure for the other end of
the hose by securing it to the regulator on the gas
bottle to complete the gas cylinder connection.
Always check for gas leaks after installation and
whenever a new or refilled gas bottle is used for
the first time.
DANGER Risk of explosion and suf-
focation! LPG bottles must not be
stored in the house.
If this occurs, close the gas bottle valve .
Check and tighten the connections immediately.
Repeat the procedure to ensure that there are no
further leaks.
Push the appliance towards the kitchen wall.
Caution: Never use a naked flame to
check for gas leaks.
DANGER Risk of explosion by
damage of the safety tube!
The safety tube must not be clamped,
bent or trapped or come into contact
with hot parts of the appliance.
Final check
1. Open gas supply.
2. Check gas installations for secure fitting and
tightness.
3. Ignite burners and check appearance of the flame.
1. Hose tip-LPG
2. Hose tip-NG
3. Safety hose
4. O-ring (gasket)
5. Clamp
Manifold
protection
plug
Manifold protector plug removal:
The manifold protection plug is inserted into the
manifold at factory level in order to protect the
manifold from being contaminated with debris. The
manifold protection plug must be removed when the
product is installed by the gas installer.
The red manifold protection plug can be removed
from the manifold by grabbing it with your fingers or if
necessary with the aid of a small pair of pliers.
Manifold
Leakage control at the connection point
Ensure that the control knobs on the control panel
are in the OFF position.
Open the valve on the Gas bottle.
Using a small paint brush, apply some soapy
water to all the connections.
If there is a leak, bubbles will appear.
If this occurs, close the gas bottle valve .
Before connecting the gas hose, make sure that the
gas hose outlet behind the product is in the same
direction as the hose outlet
If the gas hose is not in the same direction as the
hose outlet, mount it so that it does not pass through
the hot zone when connecting the hose.
3
3
X
X
X
Routing of the gas hose