User's Manual
Page 3 
 Preparing for installation. 
The extractor hood has the ability to ei-
ther recirculate the filtered air back into 
the kitchen, or to vent the filtered air 
through an outside wall.  
Decide on which option best suits you be-
fore commencing with the installation. 
•  The extractor hood is intended to be 
mounted onto a flat perpendicular kitchen 
wall capable of supporting the weight of 
the hood. (approximately 26 kg.) 
Tools required for installation: 
•  An electric drill. 
•  A 3.5 mm dia. steel drill bit. 
•  8mm and 5mm dia. masonry drill bits 
•  A star screw driver (Posi bit 2). 
•  A ratchet with a 10mm socket and a 
100mm extension. 
•  A tape measure, masking tape and a  
pencil. 
 Venting air to the outside. 
When discharging the air into a ventila-
tion shaft or directly through the wall 
into the open , please take note of the fol-
lowing: 
•  Exhaust air from the extractor hood 
must not be directed into a flue or 
chimney which is used for exhausting 
the fumes or smoke from appliances 
burning gas or fuels. 
•  Please ensure that regulations concern-
ing the discharge of exhaust air have 
been fulfilled. (SABS IEC 60335-2-31). 
For optimum extractor hood efficiency use 
a short, smooth, round air exhaust pipe with 
as few bends as possible. A 150mm diame-
ter exhaust pipe is recommended. Long box 
section, narrowed or bent pipes will hinder 
performance and increase noise levels. 
•  Connecting a 150 mm diameter pipe: 
Mount the pipe directly onto the air outlet 
on the extractor hood. 
•  Connecting a 125 mm or 100mm di-
ameter pipe: Attach a reducing connec-
tor (available from a specialist retailer) 
to the air pipe and then attach to the ex-
haust-air duct. 
Care must be taken during installation not 
to obstruct these vents. 
No ducting is required for this type of in-
stallation.
The extractor hood filters out solid particles 
before the air is re-circulated, via the vents 
on the side of the upper chimney, into the 
kitchen.
 Re-circulating filtered air. 
ceiling
Re-circulating
filtered air
ceilingceiling
Exhaust air through a dedicted pipe 
not shared with a fuel burning appliance.
DESCRIPTIONITEM QUANTITY
8mm wall plug
6mm screw
5mm wall plug
5mm screw
Self tapping screw
Slotted washer
 2
 6
10
 2