Specification
TGS FLOODLIGHTS
OUTDOOR
PS518159EN page 9
July 8, 2020 9:12 AM
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395145
CATALOG NUMBER: TGS2SCS2[F;M]SBLE40A[B;W]
Based on 10 foot mounting height. Maximum calculated value = 12.3 fc
Type V - Short - Cutoff
2.25
3.75
1.75
2.75
House Side
Street Side
Type I
Type II
Type III
Type IV
Short Medium Long
10
5
2
1
0.5
0.2
0.1
-2
-1
0
1
2
3
4
0 1 2 3 4 5 6 7
Transverse Distance in Units of Mounting Height
Longitudinal Distance in Units of Mounting Height
Iso-Footcandle Lines of Horizontal Illumination
Max cd
1/2 Max cd
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE 3 of 8
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395145
CATALOG NUMBER: TGS2SCS2[F;M]SBLE40A[B;W]
0 cd
309 cd
617 cd
926 cd
1,234 cd
180°
170°
160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°
20°
10°
0°
Luminous Intensity Polar Plot
Vertical Plane Through 90-Deg Lateral Horizontal Cone Through 2.5-Deg Vertical
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
4 of 8
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395145
CATALOG NUMBER: TGS2SCS2[F;M]SBLE40A[B;W]
FLUX DISTRIBUTION:
Downward Upward Total
House Side Lumens 1496.5 7.7 1504.3
% Fixture 49.7 0.3 50.0
Street Side Lumens 1496.5 7.7 1504.3
% Fixture 49.7 0.3 50.0
Total Lumens 2993.1 15.5 3008.6
% Fixture 99.5 0.5 100.0
ZONAL LUMENS:
Zone Lumens % Fixture
0°-10° 116.3 3.9
10°-20° 332.4 11.0
20°-30° 502.5 16.7
30°-40° 606.6 20.2
40°-50° 600.3 20.0
50°-60° 474.1 15.8
60°-70° 254.4 8.5
70°-80° 88.6 2.9
80°-90° 17.9 0.6
90°-100° 3.9 0.1
100°-110° 3.0 0.1
110°-120° 2.8 0.1
120°-130° 1.9 0.1
130°-140° 1.5 0.1
140°-150° 1.2 0.0
150°-160° 0.7 0.0
160°-170° 0.3 0.0
170°-180° 0.1 0.0
0°-90° 2993.1 99.5
0°-180° 3008.6 100.0
49.4%
49.8%
0
0.1
0.2
0.3
0.4
0.5
0.6
0 1 2 3 4 5
Street Width in Units of Mounting Height
Coefficient of Utilization
HS SS
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE 5 of 8
Photometric Data : TGS2SCS2[F;M]SBLE40A[B;W]