Specification

TGS FLOODLIGHTS
OUTDOOR
PS518159EN page 8
July 8, 2020 9:12 AM
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395146
CATALOG NUMBER: TGS2SCS2[F;M]RBLE40A[B;W]
Based on 10 foot mounting height. Maximum calculated value = 14.7 fc
Type V - Short - Full Cutoff
2.25
3.75
1.75
2.75
House Side
Street Side
Type I
Type II
Type III
Type IV
Short Medium Long
10
5
2
1
0.5
0.2
0.1
-2
-1
0
1
2
3
4
0 1 2 3 4 5 6 7
Transverse Distance in Units of Mounting Height
Longitudinal Distance in Units of Mounting Height
Iso-Footcandle Lines of Horizontal Illumination
Max cd
1/2 Max cd
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE 3 of 8
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395146
CATALOG NUMBER: TGS2SCS2[F;M]RBLE40A[B;W]
0 cd
390 cd
780 cd
1,169 cd
1,559 cd
180°
170°
160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°
20°
10°
Luminous Intensity Polar Plot
Vertical Plane Through 270-Deg Lateral Horizontal Cone Through 5-Deg Vertical
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
4 of 8
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395146
CATALOG NUMBER: TGS2SCS2[F;M]RBLE40A[B;W]
FLUX DISTRIBUTION:
Downward Upward Total
House Side Lumens 1368.4 0.0 1368.4
% Fixture 50.2 0.0 50.2
Street Side Lumens 1356.4 0.0 1356.4
% Fixture 49.8 0.0 49.8
Total Lumens 2724.8 0.0 2724.8
% Fixture 100.0 0.0 100.0
ZONAL LUMENS:
Zone Lumens % Fixture
0°-10° 142.2 5.2
10°-20° 408.1 15.0
20°-30° 591.4 21.7
30°-40° 652.9 24.0
40°-50° 525.6 19.3
50°-60° 247.8 9.1
60°-70° 112.5 4.1
70°-80° 40.9 1.5
80°-90° 3.3 0.1
90°-100° 0.0 0.0
100°-110° 0.0 0.0
110°-120° 0.0 0.0
120°-130° 0.0 0.0
130°-140° 0.0 0.0
140°-150° 0.0 0.0
150°-160° 0.0 0.0
160°-170° 0.0 0.0
170°-180° 0.0 0.0
0°-90° 2724.8 100.0
0°-180° 2724.8 100.0
49.9%
50.0%
0
0.1
0.2
0.3
0.4
0.5
0.6
0 1 2 3 4 5
Street Width in Units of Mounting Height
Coefficient of Utilization
HS SS
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE 5 of 8
Photometric Data : TGS2SCS2[F;M]RBLE40A[B;W]