Specification
TGS FLOODLIGHTS
OUTDOOR
PS518159EN page 7
July 8, 2020 9:12 AM
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395149
CATALOG NUMBER: TGS2S402[F;D;M]S[R;C][B;W]
Based on 10 foot mounting height. Maximum calculated value = 10.6 fc
Type II - Short - Cutoff
2.25
3.75
1.75
2.75
House Side
Street Side
Type I
Type II
Type III
Type IV
Short Medium Long
10
5
2
1 0.5
0.2
0.1
-2
-1
0
1
2
3
4
0 1 2 3 4 5 6 7
Transverse Distance in Units of Mounting Height
Longitudinal Distance in Units of Mounting Height
Iso-Footcandle Lines of Horizontal Illumination
Max cd
1/2 Max cd
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE 3 of 21
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395149
CATALOG NUMBER: TGS2S402[F;D;M]S[R;C][B;W]
0 cd
267 cd
535 cd
802 cd
1,069 cd
180°
170°
160°
150°
140°
130°
120°
110°
100°
90°
80°
70°
60°
50°
40°
30°
20°
10°
0°
Luminous Intensity Polar Plot
Vertical Plane Through 247.5-Deg Lateral Horizontal Cone Through 5-Deg Vertical
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
4 of 21
Cooper Lighting Solutions Photometric Lab
1121 Highway 74 South
Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P395149
CATALOG NUMBER: TGS2S402[F;D;M]S[R;C][B;W]
FLUX DISTRIBUTION:
Downward Upward Total
House Side Lumens 1333.0 5.0 1338.0
% Fixture 49.4 0.2 49.6
Street Side Lumens 1353.8 6.1 1359.9
% Fixture 50.2 0.2 50.4
Total Lumens 2686.8 11.1 2697.9
% Fixture 99.6 0.4 100.0
ZONAL LUMENS:
Zone Lumens % Fixture
0°-10° 100.4 3.7
10°-20° 289.0 10.7
20°-30° 442.8 16.4
30°-40° 539.9 20.0
40°-50° 563.8 20.9
50°-60° 452.1 16.8
60°-70° 223.0 8.3
70°-80° 65.9 2.4
80°-90° 9.9 0.4
90°-100° 2.9 0.1
100°-110° 2.3 0.1
110°-120° 1.9 0.1
120°-130° 1.5 0.1
130°-140° 1.0 0.0
140°-150° 0.7 0.0
150°-160° 0.5 0.0
160°-170° 0.2 0.0
170°-180° 0.0 0.0
0°-90° 2686.8 99.6
0°-180° 2697.9 100.0
49.1%
50.2%
0
0.1
0.2
0.3
0.4
0.5
0.6
0 1 2 3 4 5
Street Width in Units of Mounting Height
Coefficient of Utilization
HS SS
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE 5 of 21
Photometric Data :TGS2S402[F;D;M]S[R;C][B;W]