Use and Care Manual
8
1
Testing the motion sensor
□ Rotate knob on bottom of the sensor (B)
to “TEST”.
□ Turn on the power to fixture. Allow fixture to
warm up approximately 40 seconds before
testing. (Lights may not come on during
warm-up period.)
□ Aim sensor head (B) toward desired detection
area, maintaining a 5°–15° down angle to
allow moisture to drain.
□ Walk across the detection zone at the
farthest distance you wish your detector
to detect motion.
□ Adjust sensor head (B) until you get desired
results. Lights will turn off 4 seconds after
all motion stops.
NOTE: For maximum range performance, allow fixture
to operate in any mode (with power to the unit) for at
least 48 hours.
+
-
TIME
TEST
Bottom of sensor
2
Setting the ON time
□ To set the ON time, rotate knob arrow to point
to the desired time setting within the TIME
range (up to 12 minutes).
+
-
TIME
TEST
Example of knob arrow placement
to set duration of ON time
Operation
B
B