Instructions / Assembly

6
Option A Option B
6
Restoring power
□ Restore power at the electrical panel.
□ Turn on the light switch to activate the
fixture.
□ Seal the area where the mounting bracket
on the area light (A) meets the wall with
silicone sealant.
NOTE: Test fixture at night or block the photocell to
determine if the fixture is lighting properly.
A
Mounting
bracket
Photocell
sensor
5
Reinstalling the wire cover
□ Insert the wires and wire connectors into the fixture arm on the area light (A).
□ Reattach the wire cover to the fixture arm on the area light (A) with the wire cover screws removed earlier
using the M8 allen wrench (FF).
NOTE: Compatible with 1-5/8 in. mounting pole (available for purchase separately). For pole installation, use the pole clamp (DD) instead
of the wire cover.
Wire cover
screws
Wire
cover
A
Fixture
arm
Installation (continued)
Wire cover
screws
Wire
cover
FF
FF