7.4 What, if...?
ThefollowingtablelistssymptomsofmalfunctionthatmayoccurindailyoperationoftheDefensor
PH28/PH28A, together with possible causes and suggested remedies.
Symptom Cause Remedy
Unit does not work, LC display
remains dark
Unit is not connected to the mains. Connect unit to the mains.
Unitfuseblown. Have a service technician of
your Defensor supplier check
the unit.
Unit does not humidify. Humidierdrumdoesnotturn.
Humidierdrumnotcorrectly
installed.
Correctlyinstallhumidierdrum.
Gearwheelofthehumidierdrum
must engage in the driving gear
wheel.
Ambient air humidity is higher
thanselectedreferencevalue.
Noremedyrequired,changeref-
erence humidity value if neces-
sary.
Levelswitchisdefective.There-
forenoerrormessageisdisplayed
even though the water level in the
base tub is too low.
Haveaservicetechnicianofyour
Defensor supplier replace the
level switch
Room air does not reach the
set reference humidity value.
Evaporator mat not installed. Install evaporator mat.
Room temperature too high. Reduce room temperature to 20-
22°C.
Unit very dirty. Performmaintenance(see
chapter 6)
Doors or windows are open. Close doors and windows.
Prolongedventilationoftheroom.
Therefore continuous replace-
mentofthe humidiedroomair
by dry outdoor air.
Ventilateroomonlyashorttime!
Room to large. ContactyourDefensorsupplier.
Actual humidity much higher
than the reference value.
The actual humidity is higher than
thesetreferenceairhumidity.
Letunitrunningasairpurier.
Fan does not run Humidicationmode“Humidica-
tion” selected. Ambient humidity
ishigherthanselectedreference
value.
None. Unit is working properly.
Unit is in program mode. The cur-
rentlyactiveprogramsetsthefan
step to “0”.
None. Unit is working properly.
Fandefective. ContactyourDefensorsupplier.
Basetuband rotaryhumidi-
cation drum have heavy slime
accumulation.
Silver coating on the water ionisa-
tion electrodes is worn.
Haveaservicetechnicianof
yourDefensorsupplierreplace
the water ionisation electrodes.