Operating instructions
33
6.4 Reassembly of the unit
CAUTION!
BeforereassemblingtheDefensorPH28checkallcomponentsforpossibledamage.Donotreuse
damagedpartsbutreplacethembeforereassemblingtheunit
Reassembletheunitasfollows:
1
4
2
5
3
6
Install the vaporizer mat and the
retaining mesh in the humidica-
tion drum.
Slidethehumidicationdrum(with
the internal geared wheel facing
backwards) together with the base
tub into the unit.
Place the coarsedustlterwith
the blue side facing upwards (fac-
ing to the centre when mounted) or
theQuattrolterwiththeuffy
side facing the bottom (facing
outwards when mounted) in the
air intake grills, then mount the
retainerframe.
Mount the air intake grill, then tip
the swivel plate down.
Slide the water tank cart into the
unit.
Pressthe lockmechanismof the
handleonbothsidesofthecart(the
handle slides down), then tip up the
cart until the lock engages.
Important! After reinstalling the
water tank wait by the unit until the
llingsoundstops.
2.
3.
1.