Operating instructions
26
Monday 1
--.-- 45%rH H0
Monday 1
New Value
Monday 1
Old Value
Monday 1
--.-- 45%rH BA0
Monday 2
--.-- 45%rH BA0
Sunday 2
--.-- 45%rH BA0
5.5.4 Setting the starting points and the operating programs
Firstselectthedesireddayoftheweekorthestartingpoint,respectively(Monday1,Monday2.....
Sunday1,Sunday2),thendenetheoperationsettingswhichshouldbecomeactiveatthestarting
point.
Available settings: Hours (Format: hh)
Minutes (Format: mm)
Referencehumidityvaluein%rH
Operatingmode(“B”:forhumidication,“R”:forpurication(withouthumidi-
cation)and“K”:forcombinedmode(puricationandhumidication))
Fan step (0, 1, 2, 3, 4)
Factorysetting: “––:––45%rHBA0”
Notesonsetting: Aftercallingthemodicationmode setthehour,the minute,thereference
humidityvalue,theoperatingmodeandthefanstepfortheselectedstarting
point.Conrmeachsettingwiththe<Enter> key.
To deactivate a starting point (display: – – : – –) press both arrow keys simul-
taneouslywhenthehoureldashes.Conrmwiththe<Enter> key. Repeat
thisprocedurewiththeminuteeld.
Theswitchofftheunitatacertaintimeselectfanstep“0”.
(see chapter 5.5.3)
(see chapter 5.5.2)
modify
conrm
cancel
see notes on setting