Operating instructions

15
Install the air outlet grills in a way that the moist air can leave the unit unhampered and make
suretheairowisnotdirectedtowardsobstacles(pillars,furniture,etc.)orcoldouterwalls(risk
ofcondensation).
4.4 Connectingthewatersupply(PH28Aonly)
Thewatersupplyhastobeconnectedtotheunitbyaqualiedspecialistaccordingtotheillustra-
tionbelow.Theinstallationdatahastobemaintained.Theinstallationofashut-offvalvenexttothe
PH28Aismandatory.Laytheconnectionhosecarefullysothatnobodywilltripoverit.
WARNING!
Forthewaterinstallationtheunitmustbedisconnectedfromthemains(pulltheplugoutofthe
socket) and secured against inadvertent reconnection.
Important! The local regulationsregardingtheconnectionofunitstodrinkingwatersystemsmust
be observed.
Drinking water without additives:
Admissible water pressure: 0.5...6.0 bar
Admissible water temperature: 5...40 °C
Filter valve (accessory “Z261”)
WaterconnectorG3/4"(femalethread)