Owner's manual

20
average, standard deviation, number of
readings, minimum thickness reading and
maximum thickness reading are
simultaneously displayed and stored in
memory. Again, statistical summaries are
calculated for each batch during printing.
This delivers the average of a set of
average readings as required by SSPC
PA-2 guidelines.
NOTE: SSPC is a U.S.-based Society
for Protective Coatings. PA-2 is a Paint
Application specification.
Printing
Memory(3) models only
Data can be sent from the 6000 to a serial
printer, data collector or computer using
the supplied RS232 serial cable -- or
directly to the optional wireless HP IR
printer using the Gage’s built-in IR port.
Printer Output
Select PRINT?PRINT?
Choose an output option:
ALLALL: individual readings + Statistical
Summary
HISTOHISTO: Statistical Summary + Histogram
Select IR PRTIR PRT for the HP IR Printer --
or
Select a TYPETYPE as below if printing to a
serial printer or computer. If uncertain
which TYPETYPE to use, try each one, one at
a time.
TYPE BAUD Handshake
TYPE 1 9600 Xon/Xoff
TYPE 2 9600 DTR
TYPE 3 1200 Xon/Xoff
TYPE 4 1200 DTR
Each batch (group of measurements) is
printed separately. The mean, max/min