Installation manual

16
Function 1: Cause of Alarm trigger
Press button A to obtain information about the cause of the alarm last triggered. Press button B for
information about the alarm triggered previously. Hold button B to return to the last alarm.
Hold buttons A and B simultaneously to delete the trigger cause memory.
The Central Unit can store up to 10 alarm events.
Alarm triggered by: Number of flashes
Auxiliary Sensor 1 2
Open door 3
Open bonnet 4
Open luggage compartment lid 5
Ignition 6
Attempt to remove secured object (stereo, ski box, etc.) 7
Microwave Sensor 8
Glassbreake Sensor 9
Auxiliary Sensor 2 10
Function 2: Number of Remote Control Units
Press button B to learn how many Remote Control Units are connected to the alarm. The number of
units is indicated by the number of flashes.
Function 3: Alarm sounds
Press button B to activate the set alarm sound for 5 seconds. Press button B again to select the next
alarm sound and hold button B to return to the previous sound. A total of 6 different sounds are
available.
Function 4: Passive arming
Passive arming means that the alarm is switched on 12 seconds after the ignition is switched off and the
doors are closed.
Press button B to indicate:
1 flash if active arming is selected
2 flashes if active arming is selected regardless of the opened door.
3 flashes if passive arming is selected.
Press button B again to select the next function. The number of confirmation sounds indicates the status
currently set.
Function 5: The sensitivity of the Microwave Sensor
For Control purposes the sensitivity level of the detector is indicated by a number (1- 8) of short signals
in the LED.The lowest level is 1, the highest is 8. Factory setting is 3.
Press button B to indicate the valid sensitivity level. Press button B to increases the sensitivity level
while holding button B reduces the level. The number of flashes in the LED indicates the level. Selected
sensitivity level is confirmed by releasing the detector. Last choosen step will be selected sensitivity
level.