4. Installation instructions
4.1. Power the DBoard
The DBOARD is powered through one SPT 2.5/4-V-5.0 connector in the left lower part of the board. 24VDC powered,
this power supply may come from an AC/DC converter, battery, DC/DC converter, etc.
Mostly of the power supply will work with the DBOARD, but the condensers in the input may be considered.
Regulated source between 5 - 30V on 24V with current limiting and short circuit protection.
When the DBOARD is powered, the PWR LED must be ON.
4.2. Program the DBoard
Through the JT1 connector the firmware of the DBOARD should be loaded in the microcontroller memory. The micro
can access to the NFC EEPROM memory, where, as example, the user could write the configurable parameters for
commissioning the board.
5. Commissioning procedure
The commissioning procedure may be carried out by writing in the NFC memory of the board. Then the firmware may
use this data stored in the memory to control and interact with the devices attached to the board.
To facilitate the commissioning, it is based on a smartphone application developed by DEEPTRACK. This application runs
in any android smartphone with NFC implemented. In case of a bad NFC implementation of the phone there can be
some difficulties to connect, so we recommend using one of the following devices that have been validated by the
application developers:
- Huawei Y8 2018
- Motorola G6
The commissioning consists on set the parameters in every DBOARD by writing them in its NFC memory. If LoRa is
required, the application must also write the radio and unique ID data automatically in the NFC memory.
WARNING
Equipment intended to build in without enclosure. Additional
means shall be provided in order to protect user against
mechanical, thermal, and electrical shock risks. It shall be
evaluated at the final installation.
WARNING
The board should not be connected while the power supply is on.