User's Manual

Maintenance 73
Replacing UV-C Lamp
The guaranteed use hours of the UV-C lamp is 4,000 hours.
1
However, this is based on continuous use, and the actual life span of the lamp in the use envi
ronment may be different. It is recommended to replace the lamp every 1 to 1.5 years to mai
ntain the illumination level necessary to secure UV processing power.
Replace the UV-C lamp according to the replacement cycle or when an error occurs.
제품 규격에 명시된 램프(Philips TUV 36W/G36 T8) 로만 교체 바랍니다.
1 Remove the UV-C lamp protection net. Loos
en the two fixing screws on each of the upp
er and lower parts of the UV-C lamp protect
ion net.
Maintenance
5
2 Remove the two fixing pins from the upper a
nd lower parts of the UV-C lamp. Loosen th
e screws on the left and right of the pins fixi
ng the UV-C lamp.
3 Turn the UV-C lamp to align the pins and the
upper grooves.
1
실사용 환경에 따라서 차이가 있을 있습
니다.