Setup guide

Dedicated Micros ©2006
69
DS2 Network Guide
Function Description
Last database reset time This is a read only section and is generated by the unit, it
identies the last time that the database was reset.
How to Congure an Alarm Schedule
It’s possible to utilise the onboard schedule function of the unit to enable and disable alarm triggers
and VMD activation and to determine when specic record rates will be enabled. This can reduce
unnecessary alarm triggers, e.g. during ofce hours it would be unnecessary to have VMD active
and ensure the correct record rates are set during night, day and weekend time periods.
To Set the Schedule function;
Using a typical example,
Monday to Friday – Alarms/VMD are not active from 08:30
Monday to Friday – Alarms/VMD become active from 18:30
Weekend – Alarms/VMD are active all weekend
1. Enter 24:00 in the Day box adjacent to Sunday and Saturday.
2. Enter 24:00 in the Night box adjacent to Sunday and Saturday.
3. Enter 18:30 in the Night box adjacent to Monday, Tuesday, Wednesday, Thursday and
Friday.
4. Enter 08:30 in the Day box adjacent to Monday, Tuesday, Wednesday, Thursday and
Friday.
5. Save the information congured by selecting Save Settings!
Note: 24:00 -24:00 = Schedule 24 hour enabled, 00:00 – 00:00 = Schedule disabled.
Function Description
Schedule This is a seven day schedule that allows alarms and VMD to be
enabled or disabled at times during the day.