Setup guide
Dedicated Micros ©2006
69
DS2 Network Guide
Function Description
Last database reset time This is a read only section and is generated by the unit, it
identies the last time that the database was reset.
How to Congure an Alarm Schedule
It’s possible to utilise the onboard schedule function of the unit to enable and disable alarm triggers
and VMD activation and to determine when specic record rates will be enabled. This can reduce
unnecessary alarm triggers, e.g. during ofce hours it would be unnecessary to have VMD active
and ensure the correct record rates are set during night, day and weekend time periods.
To Set the Schedule function;
Using a typical example,
Monday to Friday – Alarms/VMD are not active from 08:30
Monday to Friday – Alarms/VMD become active from 18:30
Weekend – Alarms/VMD are active all weekend
1. Enter 24:00 in the Day box adjacent to Sunday and Saturday.
2. Enter 24:00 in the Night box adjacent to Sunday and Saturday.
3. Enter 18:30 in the Night box adjacent to Monday, Tuesday, Wednesday, Thursday and
Friday.
4. Enter 08:30 in the Day box adjacent to Monday, Tuesday, Wednesday, Thursday and
Friday.
5. Save the information congured by selecting Save Settings!
Note: 24:00 -24:00 = Schedule 24 hour enabled, 00:00 – 00:00 = Schedule disabled.
Function Description
Schedule This is a seven day schedule that allows alarms and VMD to be
enabled or disabled at times during the day.