Setup guide

Dedicated Micros ©2006
55
DS2 Network Guide
1. Click on Alarms/VMD -> Alarm/VMD Reporting.
2. The primary connection uses the network port.
3. To set up the secondary connection, enter the IP address of the target PC running
NetVu ObserVer and the EDP in the ‘Host’ column.
4. In the ‘Prole’ column, enter the prole name created in the last step.
Note:
Use the correct username/prole label congured in the PROFILES le. This informs the
system which settings to use.
1. Plug the TA into COM port 2.
2. Click on System->Serial Ports & Telemetry
3. Select Serial 2 (round dot) to edit these settings.
4. Use the drop down list select your type of TA (or modem).
Note: If your TA is not listed then contact Dedicated Micros Technical Support.
NOTE: The ISDN TA could be replaced with a modem which then dials another modem connected
to a PPP Server.
5. Click on the ‘Save’ icon on the bottom right of the screen.
6. Reset the unit