Setup guide

Dedicated Micros ©2006
44
DS2 Network Guide
Contact Number The Auxiliary input and the additional alarm modules support
sixteen input contacts any of these can be allocated as the alarm
input trigger.
Normally Closed Contact The alarm trigger can be congured as normally open (default) or
normally closed.
Preset The preset position is the position the camera will move to when
the alarm is triggered.
Zone Trigger It is possible for a camera specic alarm to also trigger an alarm
zone. If the input is to trigger a zone as well as send a camera to
a preset position this option must be enabled.
How to Congure the Relay Connections
The unit supports a number of onboard relay connections and can also integrate additional relay
modules via the 485 bus connection.
These relays can be triggered under specic conditions; on receipt of an alarm, notication of VMD,
etc or they can be permanently allocated for set functions.
This section details how to congure the default actions supported on the unit.
Note: If the defaults are not set this allows the onboard relays to be available to be automatically
triggered on alarm, this is congured within the Alarm/VMD -> Alarm Zone option.
To congure the relay output settings.
1. Select System -> Relay Setup. There are six default settings that can have any of the
onboard or additional relay modules selected as the output for the default function.
2. Global Alarm when a global alarm is received select the relay that will be automatically
triggered from the drop down lists, select from the onboard relays (AUX) or the
additional 485-bus modules (Module 1 or Module 2) then select the relay number (1 to
6 for onboard or 1 to 16 for the additional modules).
3. The same process can be carried out for Global VMD, Global Camera Fail, Schedule
Notication, Primary Signalling Failure and Weekend Notication.
4. Save the conguration by selecting Save Settings!
Note: The Schedule Notication, Primary Signalling Failure and Weekend Notication are only
available when the Advanced Alarms option is enabled.
Note: The relays that are allocated for the default function in this page will not be available for
testing in the Relay Test Page (within the Tools menus).
Function Description