Setup guide

Dedicated Micros ©2006
41
DS2 Network Guide
Function Description
Select Zone Cameras This allows you to select one or more cameras that will be
associated with the Alarm Zone being congured. Each camera
will become part of the ‘alarm sequence’ when this alarm zone is
triggered.
Alarm Zone Actions (select all) There are numerous actions that can be included in any of the
zones being congured, this option will enable all actions.
Zone on entry route This is part of the Advanced Alarm Features and will create
deferred alarms while the entry time is active. The primary alarm
input will initiate the ‘entry counter’ to count down; this has specic
alarm areas associated with it. If someone enters the specied
alarm areas during the count down process the alarm will not be
triggered allowing them to reach the alarm panel to switch the
alarm off.
Zone on exit route This is part of the Advanced Alarm Features and will create
deferred alarms while the exit timer is active. This is the similar
to the zone on entry option, but works in the reverse, this allows
an Operator to switch on a building alarm and will give them a set
time period to exit the building and allow them to pass through
specied alarm areas without triggering the alarm.
Entry Initiator This is part of the Advanced Alarm Features and will trigger the
entry timer if the system is set. This is a count down timer that
will automatically start when the ‘primary’ alarm trigger (e.g.
front door) is actioned and this ensures the alarm system is not
activated by other specied alarm triggers for the set time
Exit terminator This is part of the Advanced Alarm Features and will trigger the
exit timer if the system is set. This is a count down timer that will
automatically start when the alarm is activated and ensures the
alarm system is not activated by other specied alarm triggers for
the set time, i.e. allowing the Guard to leave the building.
Text Only Alarm This is not currently supported.
Create Database Entry An alarm entry will be added to the database, the zone title will be
used as part of the entry information.