Setup guide

Dedicated Micros ©2006
17
DS2 Network Guide
2. Select System -> Serial Ports & Telemetry.
3. Using the drop down list on the associated Communication port (Serial 3 (Bus A) or
Serial 4 (Bus B)) select RS232/485 Telemetry.
4. Select the relevant telemetry type from the list of supported protocols.
5. Enter the dome/PTZ standard settings for:
- Baud rate
- Parity
- Data bits
- Stop bits
- Flow control
6. Ensure the address of the dome/PTZ camera is the same as the video input number on
the unit, e.g. Video input 15 would equate to the dome/PTZ camera being address 15.
7. Remember to save the changes you have made by selecting Save Settings!
8. Select Cameras -> Camera and Record Setup and select the telemetry protocol from
the Telemetry list for the corresponding camera.
Function Description
Serial 1 & Serial 2 Serial ports 1 & 2 are RS-232 ports and can have the following
port usage assigned; off, debug, general purpose, PPP, text in
image and RS-232 telemetry.
Modem/TA When the serial port has been congured for PPP it is necessary
to select from one of the supported modems to identify the device
connected to the unit, refer to table below for supported modems/
TA’s.
Serial 3 & 4 (Bus A and Bus B) Serial ports 3 & 4 are RS-232, RS-422 and RS-485 ports and
can have the following port usage assigned; off, debug, general
purpose, text in image, RS232/485 telemetry.
Telemetry type This is the list of serial telemetry protocols that are supported on
the unit.