Alarm
This report is generated when an alarm is received on the unit.
ALARM?<name>&<time>&<lat>&<long>&<speed>&<course>&<zone>&<camera>&<title>
name This is the system name congured on the unit.
time This is the local julian time of the message. The julian time is the
number of seconds since 00:00:01 hour on January 1st 1970. If
the Verbose message option has been enabled on the unit this
message will be in a human readable format.
lat This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
long This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
Speed This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
course This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
zone This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
camera This is the video input number that is directly associated with the
alarm on the unit.
title This is the alarm title allocated to the alarm that forced the SMS
message.
VMD
This report is generated when activity has been identied on the unit.
VMD?<name>&<time>&<lat>&<long>&<speed>&<course>&<zone>&<camera>&<vmd zone>
name This is the system name congured on the unit.
time This is the local julian time of the message. The julian time is the
number of seconds since 00:00:01 hour on January 1st 1970. If
the Verbose message option has been enabled on the unit this
message will be in a human readable format.
lat This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
long This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
speed This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
course This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
zone This parameter is not relevant to the unit and included to support
other Dedicated Micros platforms.
camera This is the video input number that is directly associated with the
alarm on the unit.
vmd zone VMD zones are congured on the unit, this identies the zone that
has been activated to initiate the SMS message.
Camfail
This report will be generated if the unit identies that any of the video inputs does not have a 1V
peak-to-peak signal.
CAMFAIL?<name>&<time>&<lat>&<long>&<speed>&<course>&<zone>&<upper>&
<lower>