Data Logging
The unit can log changes in the forces applied to the accelerometer.
Logging Mode Various logging modes are available. Select either ‘Vehicle Logging’,
‘Vehicle Analysis’ or ‘Simulated Logging’ to display default settings for
each specic logging task. Selecting ‘User Dened’ allows the user to
congure parameters as required.
Alarm Select the alarm input to be logged.
Channel Select the Data Channel to be logged;, in Vehicle Logging, the options
are Panic, Brake, Accel, Turn_Left, Turn_Right, Beacon or Siren.
On Enable or disable the feature.
N/O Select if the alarm is normally open or closed.
DSK Log for the associated alarm is saved in the Logdir/Data.
Detection Select the type of Voltage detection to be logged
Tacho Select the Tacho/Speedo channel.
Channel This can monitor the Tacho or the Speed.
On Enable or disable the feature.
DSK Log the Tacho data to disk
RPM Ratio Allows the reading to be multiplied up to give an easily understandable
display.