Alarm Protect sec This is the minimum time period in seconds (from the start of the
alarm) that is protected from being overwritten. This time will include
the alarm trigger, the pulse extension and any post alarm recording. It
will not include pre-alarm images.
Zone Input Rule This determines which input(s) will trigger the zone alarm:
Input This sets an input or system function as the primary alarm trigger.
Select from Alarms 1-32, Activity 1-16, Preset 1-16, Disk Low, Disk
Full, Panic, Archiving Slow, Archiving Fault, Virtual 1-16, and Keyword
Channel 1-32 (which will trigger the Alarm if any or the 32 programmed
keywords are detected on the selected channel).
Zone OR Input The Zone OR Input identies an alternative input that can also be used
to trigger the zone alarm. This means an alarm trigger can be received
on the Zone Alarm Input or the Zone OR Input for the zone to
be activated.
Zone AND Input
The Zone AND Input identies that an alarm trigger needs to be
received on both the Zone Alarm Input and the Zone AND Input for
the zone to be activated and the alarm action to the
automatically initiated.
Zone NOT Input
The unit will only issue the alarm actions if the trigger is received on
the zone alarm input and NOT on the Zone input.
Alarm 24Hr This option can be enabled for alarms that do not require change at
any time and are to remain as programmed i.e. Panic Alarm. When this
is selected, the Set, Unset and Override options
are disabled.
Entry Route Zone This creates deferred alarms along a specied route while the
entry time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the entry
route during the countdown will result in the alarm being triggered
immediately. This allows staff entry without triggering an alarm prior to
switching the system to Set mode.
Exit Route Zone This creates deferred alarms along a specied route while the exit time
is active. This is in compliance with BS8418 (the British Standard for
remote video reporting centres). Diverting from the exit route during
the countdown will result in the alarm being triggered immediately. This
allows staff to exit without triggering an alarm.
Exit Terminator This will trigger the exit timer if the system is set. A countdown timer
will automatically start when the alarm is activated and ensure the
alarm system is not activated by other specied alarm triggers for the
Set time i.e. allowing a Guard to exit a building.
Entry Initiator This will trigger the entry timer if the system is set. A countdown timer
will automatically start when the ‘primary’ alarm trigger i.e. front door,
is actioned. This ensures the alarm system is not activated by other
specied alarm triggers for the set time
Enable in Unset Each alarm can be congured to be active when the unit is in a specic
operation mode. Enable this for the zone alarm to be active in Unset
operation mode.
Enable in Set Each alarm can be congured to be active when the unit is in a specic
operation mode. Enable this for the zone alarm to be active in Set
operation mode.
Enable in Override Each alarm can be congured to be active when the unit is in a specic
operation mode. Enable this for the zone alarm to be active in Override
operation mode.
Note: Unset, Set and Override modes can be given more recognisable titles i.e. Day, Night,
Weekend via the Schedule menu (Record Settings->Schedule).