Zone Input
This menu allows the conguration of established alarm zones. A single or multiple trigger can be
used to generate an alarm. It is possible to allocate up to 32 alarm zones to carry out a combination
of actions. Use these options in conjunction with the Zone Actions menu.
Entry timer This is the number of seconds allowed for the user to enter the zone
and disable the alarms. If the alarm is not disabled within this period
the alarm will be triggered.
Exit timer This is the number of seconds from the alarm being set within which
the user must exit the set zone. If the user is still within the zone after
this time period the alarm will be triggered.
Zone An alarm zone can be established to logically groups alarms and
initiate actions when an alarm is activated, there are 32 congurable
zones.
Title This information is stored along with the relevant images in the
database, ensure this has relevance to the alarm zone.
Pre-Alarm sec This is the time period prior to the start of the alarm included with the
alarm recording for archive. These images will also be protected from
being overwritten.
Note: It is recommended that the Pre-Alarm option be set to the same value as the Pre-Trigger
setting in the “Prole Record“ menu. This will ensure successful playback of high quality
Pre-Trigger images. High quality pre-trigger images will only playback properly if review
(playback) starts prior to the pre-trigger initiation.