Nuisance This is a repetitive detector value. When an alarm is received on the
unit, it will store the alarm time and monitor the number of times the
same detector is triggered within an hour period. If the detector is
triggered the number of times entered here, the unit will de-activate
this detector from triggering an alarm for an hour. The unit will continue
to monitor the detector and check how many times it is triggered during
this period. If it is again triggered more than the amount set in the
nuisance counter, it will remain de-activated for another hour. This will
continue until the trigger value falls below the nuisance count setting.
To disable this feature, leave the setting as ‘0’.
Stuck Time (min) If any of the alarms/detectors are active for a period longer than
specied here, they will automatically be omitted. This time period is
set in minutes.
Reset (Red) This button will restart the unit.
Relays (Green) Opens the Alarm Settings -> Global Actions page
Status (Yellow) Opens the System Settings -> Status -> Alarm Status Page
Zone In (Blue) Opens the Zone Inputs page (below).
Refresh (Purple) Refreshes the current page.