Operating Instructions and Installation Instructions
AD Holdings ©2011
67
TransVu Express
Note: The arrow button displayed next to each textbox allows settings to be replicated for those
cameras listed below. This will only affect the adjacent option i.e. Mode arrow will replicate
the Mode setting to all cameras below the clicked arrow.
Note: To disable one day, set both times to 00.00. To have the prole recording all 24 hours of a
day, set both times to 24.00.
Keyswitch A Keyswitch can be used to switch the recording prole (Unset/Set).
With Keyswitch enabled
Enable-N/O Select if the Keyswitch is to be normally open (UNSET). Then choose
a contact to be used in a specic zone as the Keyswitch.
Enable-N/C Select if the Keyswitch is to be normally closed (SET). Then choose a
contact to be used in a specic zone as the Keyswitch.
Enable EOL Select to congure the Keyswitch for EOL. The End Of Line (EOL)
option enables the Keyswitch to detect any changes in the electronic
input resistance. A change outside the expected values will result in
a Tamper Alarm (short circuit or open circuit) being detected and the
system switching to alarm mode.
on Species which of the available contacts will trigger the keyswitch
function.
in Species which of the 32 available zones will be triggered by the
keyswitch function, which will then follow the rules congured on the
Alarm Settings->Zone Inputs page.