Operating Instructions and Installation Instructions
AD Holdings ©2011
49
TransVu Express
Camera Setup
This menu allows the conguration of active camera channels.
IMPORTANT: The menu options displayed will differ depending on the camera ‘Type’ and ‘IP
Mode’ selected.
Note: Ideally any setup options available locally on the camera should rst be used to best obtain
a suitable image quality.
Mono/Colour Camera
Load Video Window (grey) Press to initiate the applet to display the camera view.
Camera Select a camera channel for review and adjustment.
Camera Nuisance Count This is a repetitive detector value. When a camera failure alarm
is received on the unit, it will store the alarm time and monitor the
number of times the same alarm is triggered within an hour period. If
the detector is triggered the number of times entered here, the unit will
set the camera to ‘No Connection’. To disable this feature, leave the
setting as ‘0’.
Title Assign a recognisable name to the camera. This will be displayed in
all references to the camera in the both the Conguration and Viewer
menus.
Type The settings will default to ‘Colour’. If Monochrome cameras are used,
select ‘Mono’. Selecting ‘Mono’ will remove colour patterning. Select’
‘IP’ for an IP Camera. If a particular channel is not in use or the camera
has failed, select ‘No Conn’.