To install the web pages:
1) Open FTP and telnet/serial sessions as above;
2) At the debug prompt type < devcopy a:\web.zip \ash\web.zip >
3) Uploading to ash memory takes several seconds If the process is successful, a
message on screen will conrm success.
4) Erase the le ‘web.zip’ from the a: drive.
Record and Power Management Modes
TransVu Express can be congured with certain parameters at build time.
Record Mode
There are two methods of recording with the TransVu Express, PAR le recording or AVI le
recording. A new system always defaults to PAR le recording.
PAR Recording
This is the conventional recording mode. When the unit is congured in this way, video is stored in
PAR format organised into video partitions.
AVI Recording
Video is recorded to AVI les.
To revert to PAR les;
If the TransVu Express was set up to record using AVI it can be reset to record with PAR les.
1) Open FTP and telnet/serial sessions as detailed above;
2) At the debug prompt type < <setlock 00000000>
3) Re-format the disk using <FDISK>
Note: It is essential that disks are re-formatted when changing record methods
To revert to AVI les:
If the TransVu Express was set up to record using AVI it can be reset to record with PAR les.
1) Open FTP and telnet/serial sessions as detailed above;
2) At the debug prompt type <setlock 125869A8>
3) Re-format the disk using <FDISK>
Note: It is essential that disks are re-formatted when changing record methods.
Power Management Mode
A new system congured for either PAR or AVI recording will power up regardless of the status of
the Ignition Sense input and Power Management Enable checkbox in the web pages.
Boot on Ignition
The ignition line controls boot up and safe shutdown (when enabled in web pages).
Record on Ignition
The ignition line controls record start/stop.
To congure PAR le systems for ignition control:
1) Open FTP and telnet/serial sessions as detailed above;
2) At the debug prompt type <avr_set FE>
3) The status can be conrmed by entering: <avr_ver> which will return the power
management version number followed by FE.
Power management can now be enabled or disabled via the web pages.
To congure AVI le systems to use Ignition Sense status to start/stop recording:
Note: The AVI le system will start regardless of the Ignition Sense status
1) Open FTP and telnet/serial sessions as detailed above;