Operating Instructions and Installation Instructions

AD Holdings ©2011
103
TransVu Express
Remote Reporting
This menu details the conguration requirements for the unit to report to a Remote Video Receiving
Centre (RVRC) following alarm activation.
Note: This menu will only be displayed if ‘Remote Reporting’ is selected in the
System Settings->Features menu.
Primary Hostname This is the IP address or URL of the initial host that the unit will
transmit an alarm message to.
Primary Dial Prole It is possible for the alarm message to be transmitted via the Ethernet
network.
Secondary Hostname If the unit is unable to contact the primary host, an alternative route
can be identied via a secondary host. If there is only one alarm
receiving IP address, you must enter the details in both the primary
and secondary connection settings.
Secondary Dial Prole It is possible to select a separate dial prole for the secondary host.
Public (NAT) Address This is the public IP (or domain name) for a unit connected to the
Internet via a NAT Router or Firewall. This eld should be left blank if
NAT is not used e.g. a private network.
Video Server Port This eld allows the RVRC to connect to the unit through a router that
is using port forwarding e.g. if the video server does not appear on port
80 (HTTP), to the external network. Enter the port number used for
forwarding here if required.
Alarm Server ref. ID This is the reference name/ID that will be presented to the RVRC
viewing application. It should therefore have some signicance to the
Operator.
Remote Alarm Reporting This must be enabled for the unit to automatically connect on alarm.