Instruction manual

29
General
Certification CE EMC, FCC CLASS A, CSA
Electrical
Input Voltage
18 to 30VAC; 24VAC nominal, 24VDC
Power Requirement 24VAC/VDC 1A
Power Consumption Maximum 20W
Alarm Output 4 Normal relays 24VDC/1A Max. (selectable NC/NO)
Alarm Input 8 Normal dry contact (selectable NC/NO)
Control RS-485/422 baud rate: 2400~230k bps (default: 9600bps)
Access Time 0.75 second maximum preset recall time
ID (Camera Address) 999
Mechanical
Dimension See Figure 10
Weight Approx 1.2 kg
Pan Angle
360° continuous rotation
0.1° to 90°/sec. (proportional to zoom)
Speed
Preset Speed: 380°/sec
Repeatability
0.2°
Flip
Rotate 180° at bottom of tilt
Autoscan 8 auto scan include vector scan
Preset Position 240 positions with camera status (16-character title)
Tour 8 tours
Pattern Four patterns, 240 second
On-Screen Display Displays camera ID and area name on screen
Environment
Operating temperature
0°C to 50°C (32°F to 122°F)
Operating humidity 0 to 90%RH (non-condensing)
Storage temperature
-20°C to 60°C (4°F to 140°F)
Specifications are subject to change without notice.
Figure 10 – Dimension