Operating instructions
Dedicated Micros ©2010
89
SD Advanced
Zone Actions
This menu allows actions to be allocated to individual alarm zones; Primary and Secondary cameras 
can be allocated to the zone and actions undertaken following alarm activation. This page should be 
congured in conjunction with the Zone Inputs menu.
Zone  Select a zone (alarm) to congure.
Alarm Colour  This displays the local alarm text in the selected colour and can 
be useful in prioritising alarms. Options available are Red, Green, 
Blue, Yellow, Cyan and Magenta.
Secondary Cameras  This setting gives the facility to assign additional cameras to the 
zone. These cameras will become part of the alarm sequence 
shown in the Viewer menus when the alarm zone is triggered.
Create Database Entry  An alarm activation will be added to the database. The zone title 
will be used as part of the entry information. 
Alarm Relay  Select to trigger an alarm relay following zone activation. Select 
the specic relay via the ‘Relay’ option.
Prole Change  Select to enable the unit to switch from Normal to Event recording  
following alarm zone activation.
Play Audio  It is possible to play associated audio upon zone alarm activation.
Alarm Reporting  This must be enabled to allow the unit to send an alarm 
notication to an external destination i.e. an RVRC reporting via 
NetVu ObserVer.
Archive  Select to ensure the unit automatically downloads alarm images 
via an FTP connection to an FTP server.