Operating instructions

Dedicated Micros ©2010
62
SD Advanced
IP Camera
The following menu will be displayed when ‘IP Camera’ is selected. The menu allows the
conguration of connected IP Cameras (cameras connected directly to a network broadcasting a
digital video stream from an IP address). It can also connect to other NetVu Connected DVRs and
treat one of the network feeds from that DVR as a digital video stream.
Camera Select a camera channel for review and adjustment.
Camera Nuisance Count
Title Assign a recognisable name to the camera. This will be displayed
in all references to the camera in the both the Conguration and
Viewer menus.
Type The settings will default to ‘Colour’. If Monochrome cameras
are used, select ‘Mono’. Selecting ‘Mono’ will remove colour
patterning. Select’ ‘IP’ for an IP Camera. If a particular channel is
not in use or the camera has failed, select ‘No Conn’.
IMPORTANT: The menu options displayed will differ depending on the camera ‘Type’
selected here.
Fail Rep Select this option to generate a Failure report in the event of
camera connection failure.
Termination The unit will automatically terminate the camera input with 75Ω.
This should be disabled if the video feed is looped through to
another device.
Telemetry If a telemetry capable camera is connected, the appropriate
control protocol should be selected from the accompanying drop
down list. Refer to ‘Appendix G’ for details of supported
telemetry protocols.