Operating instructions
Dedicated Micros ©2010
61
SD Advanced
Termination The unit will automatically terminate the camera input with 75Ω.
This should be disabled if the video feed is looped through to
another device.
Telemetry If a telemetry capable camera is connected, the appropriate
control protocol should be selected from the accompanying drop
down list. Refer to ‘Appendix G’ for details of supported
telemetry protocols.
Default to preset If a telemetry camera has been assigned a preset position, select
the chosen preset position here. Also enter the time period (in
minutes) of inactivity which will result in the camera moving to
its preset position. Refer to Viewer menus->Program Page for
guidance on assigning camera presets.
Colour Select a colour value from -8 to +8 via the slidebar or enter a
number directly into the accompanying textbox.
Brightness Select a contrast value from -8 to +8 via the slidebar or enter a
number directly into the accompanying textbox.