Termination  The unit will automatically terminate the camera input with 75Ω. 
This should be disabled if the video feed is looped through to 
another device. 
Telemetry  If a telemetry capable camera is connected, the appropriate 
control protocol should be selected from the accompanying drop 
down list. Refer to ‘Appendix G’ for details of supported 
telemetry protocols.
Default to preset  If a telemetry camera has been assigned a preset position, select 
the chosen preset position here. Also enter the time period (in 
minutes) of inactivity which will result in the camera moving to 
its preset position. Refer to Viewer menus->Program Page for 
guidance on assigning camera presets.
Colour  Select a colour value from -8 to +8 via the slidebar or enter a 
number directly into the accompanying textbox.
Brightness  Select a contrast value from -8 to +8 via the slidebar or enter a 
number directly into the accompanying textbox.