Operating instructions
Dedicated Micros ©2010
140
SD Advanced
Event Settings
This menu allows actions to be established and congured for the Oracle Dome camera following
an alarm event. A Home position can be established for the camera and the delay time set for what
period of inactivity is required before the camera will be sent to its home position.
Camera Selected camera channel.
Camera Title Displays the title assigned to the selected camera channel.
Event Name If required, enter a specic name for the alarm event.
Type Select the alarm type from:
EOL (End of Line), NC (Normally Closed), NO (Normally Open)
or Disabled.
Action Select a preset position or a patrol action for the camera upon
alarm event.
Relay Select an action for the relay. Select ‘Momentary’ for the relay to
momentarily switch state. Select ‘Duration’ to switch relay status
for the duration of the alarm.
Home (Grey) Select to send the camera to its predetermined home position.
Action Select a preset or patrol from the accompanying drop down list.
This preset/patrol will now be set as the cameras ‘home’ position.
Delay Select the time ( in seconds) for which the camera is inactive i.e.
no operator input, before returning to its home position.
Save (Grey) Select to store Event Settings to the unit and the Oracle Dome
camera memory.