Operating instructions
Dedicated Micros ©2010
127
SD Advanced
Keyword
This menu allows specic keywords received via the text stream to be congured and enabled as
event triggers. The ‘Enable Keywords’ function need to be activated in the ‘Text in Image’ menu for
this feature to operate.
Text Keyword The unit can be congured to react to dened keywords appearing
in text data and treat them as alarm zone inputs. In turn this
generates events in the event database. The advantage of this
feature is that it allows the user to see exactly which keyword
triggered an alarm. A total of 32 Keywords can be congured and
each can be up to 20 characters in length. All of the keywords will
be active on the selected Zone keyword channel, refer to “Zone
Input -> Input”.
Note: Increasing the number of keywords can signicantly increase the number of stored events.
Note: Refer to ‘Text In Image’ and ‘Serial Ports’ for further guidance on integrating text data.