Alarm Server ref. ID This is the reference name/ID that will be presented to the RVRC
viewing application. It should therefore have some signicance to
the Operator.
Remote Alarm Reporting This must be enabled for the unit to automatically connect
on alarm.
Remote Cam Fail Reporting Enabling this option ensures the unit reports camera failure on
any of the inputs to the RVRC.
Remote Startup Reporting This will send an alarm report when the unit starts up. Any system
resets will be identied.
ARC Ping Enabled
Should the modem/router at the Alarm Receiving Centre be dormant,
the unit will ‘Ping’ the ARC prior to sending reporting data.
Alarm Responder Port This species the network port number used for reporting to the
alarm server. In normal circumstances this should be left at the
default value (23).
Dial Retry Time (secs) If the initial connection attempt fails, the unit will wait for the
specied time period (in seconds) before attempting to re-connect.
Dial Count This identies the number of times the unit will attempt to connect
after a failed attempt. A setting of ‘0’ means no limit and the unit
will continue to try and connect until successful.